AN9640B臺式安全性能綜合測試儀@%AN9640B
| 主要特點: |
| 適用對象: |
各類家電生產制造商,以及進行家電安全規范檢測認證的機構,科研院所
| 技術參數: |
|
技術參數
|
AN9640B
|
|
|
顯示方式
|
240×128點陣 藍屏
|
|
|
隔離變壓器容量
|
單相:2000W 6000W
|
|
|
過流保護門限
|
電流大于30A,超過5s保護
|
|
|
報警方式
|
聲、光報警
|
|
|
接口功能
|
RS232、97電源接口、報警燈接口、遙控接口
|
|
|
選配功能
|
RS485接口、打印接口、腳踏開關接口、開關量接口
|
|
|
蜂鳴器報警聲音
|
可開啟,可關閉
|
|
|
測試組數
|
15個測試組,每組7個測試步
|
|
|
接地電阻測試
|
空載輸出電壓
|
<12V
|
|
電流設定范圍
|
AC 10A 25A 50Hz/60Hz 1A/步
|
|
|
電流精度
|
±(3%×設定值+0.18A)
|
|
|
電流穩定度
|
小于0.4% (10A電流,100mΩ)
|
|
|
接地電阻測量范圍/精度
|
10~600mΩ ±(3%×讀數+5個字)
|
|
|
接地電阻上限設定范圍
|
10A:10~600mΩ;25A:10~300mΩ;1mΩ/步
|
|
|
接地電阻下限設定范圍
|
0~100mΩ
|
|
|
補償電阻范圍
|
0~200 mΩ自動測量,可開、關
|
|
|
接地電壓測量范圍/精度
|
30~7500mV ±(3%×讀數+50mV)
|
|
|
接地電壓上限設定范圍
|
30~7500mV 1mV/步
|
|
|
接地電壓下限設定范圍
|
0~3000mV
|
|
|
補償電壓范圍
|
0~1000mV 自動測量,可開、關
|
|
|
時間設置范圍/分辨率
|
1~999s 1s/步
|
|
|
絕緣電阻測試
|
額定輸出負載/電流
|
2VA(1000V/2mA) 2mA
|
|
輸出電壓范圍/調整率
|
DC 500V/1000V <1%(從空載到滿載)
|
|
|
輸出電壓紋波
|
<1% (純阻1000V/1mA)
|
|
|
輸出電壓精度/分辨率
|
±(3%×設定值+3V) 5V
|
|
|
絕緣電阻測量范圍/精度
|
≤100MΩ:±(3%×顯示值+3個字);
>100 MΩ:±(8%×顯示值+8個字)
|
|
|
絕緣電阻上限設定范圍
|
2000 MΩ
|
|
|
絕緣電阻下限設定范圍
|
0.3~2000MΩ 0.1MΩ/步(≤100MΩ),1 MΩ/步(>100MΩ)
|
|
|
測試時間范圍/分辨率
|
1~999s 1s/步
|
|
|
交流耐壓測試
|
額定輸出負載
|
100VA (AC:5000V/20mA)
|
|
輸出電壓范圍頻率調整率
|
500~5000V 50Hz/60Hz <3% (從空載到滿載)
|
|
|
輸出電壓設定范圍精度
|
靜態:AC,500~5000V;±(3%×設定值+10V)
|
|
|
擊穿電流測量精度
|
±(3%×讀數+0.03mA)
|
|
|
擊穿電流預置報警范圍
|
上限:0.10~20.00mA;下限:0.03~10.00mA;0.01mA/步
|
|
|
補償電流范圍
|
0.00~10.00mA,自動測量,可開、關
|
|
|
測試時間范圍
|
1~999s 1s/步
|
|
|
緩升時間范圍
|
0~100s 1s/步
|
|
|
泄漏測試
|
輸出電壓范圍
|
外置電源或隔離裝置輸入
|
|
泄漏類型設定
|
靜態泄漏,動態泄漏
|
|
|
輸出電壓測量范圍精度
|
AC 60~280V/45~65Hz: ±(0.5%×顯示值+2個字)
|
|
|
泄漏電流設定范圍
|
上限:0~9.999mA 0.001mA;下限:0mA
|
|
|
補償電流設定范圍
|
0~1000uA,自動測量,可開、關
|
|
|
泄漏電流測量范圍精度
|
0.050mA~9.999mA/ DC~10kHz:±(3%×顯示值+10uA);
10k~1MHz:±(5%×顯示值+50uA)
|
|
|
測試時間范圍
|
1~999s 1s/步
|
|
|
功率測試
|
輸出電壓范圍
|
外置電源或隔離裝置輸入
|
|
功率設定范圍分辨率
|
上限:6~6000W 下限:0~6000W 1W/步
|
|
|
輸出電壓測量范圍精度
|
AC 60~280V 45~65Hz:±(0.5%×顯示值+2個字)
|
|
|
電流測量范圍精度
|
AC 0.030~3.999A,4.00~25.00A;
45~65Hz:±(0.5%×顯示值+0.020A)
|
|
|
有功功率測量范圍精度
|
10.0~199.9W:±(0.5%×顯示值+5W);
200~6000W:±(0.5%×顯示值+30W)
|
|
|
功率因數測量范圍精度
|
0.100~1.000;±(2%×顯示值+2個字)
|
|
|
測試時間范圍
|
1~999s 1s/步
|
|
| 儀器配件: |
|
配件名
|
型號
|
|
測試鉗
|
AN965-01
|
|
輔助電源線
|
AN965-05
|
|
接線盒
|
AN965-02
|
AN9640B integrated test bench safety performance tester@%AN9640B
Main features:
In line with the new national standard and verification regulation of safety, to improve the accuracy of ± 3%;
■ ARM kernel 32 bit ADUC7027 microprocessor;
■ test ground, insulation, pressure, leakage, power;
■ password can be set, the alarm switch, voltage slow rise, grounding resistance can display voltage;
■ 15 groups of test conditions, provide variouscompensation memory;
■ overcurrent and overvoltage transfinite acousto-optic alarm;
■ provides remote control, RS232 communication (485 available), and the 97 communication power supply;
■ output terminal security protection.
Applicable objects:
All kinds of home appliance manufacturers, as well as themechanism for home appliances Safety standardcertification testing, Research Institute
Technical parameters:
Technical parameters of AN9640B
Display mode: 240 x 128 dot matrix screen
Isolation transformer capacity single-phase: 2000W6000W
Over current protection threshold current is greater than 30A, more than 5S protection
Alarm sound, light alarm
The interface function of RS232, 97 power supply interface, alarm lamp interface, remote control interface
The matching function is RS485 interface, printer interface, foot switch interface, switch interface
The buzzer alarm sound can be opened, closed
The test group number 15 test groups, each group of 7step test
Grounding resistance test no-load output voltage <12V
Current setting range AC 10A 25A 50Hz/60Hz 1A/
The current accuracy of ± (3% × set value 0.18A)
The current stability of less than 0.4% (10A current, 100mΩ
Grounding resistance measurement range / precision of 10 ~ 600m Ω ± (3% × reading + 5 words)
Grounding resistance limit the range of 10A:10 ~ 600mΩ; 25A:10 ~ 300m Ω 1m Ω / s
Grounding resistance limit setting range 0 ~ 100m
Compensation resistance range 0~200 m Ω automatic measurement, can be opened, close
Grounding voltage measurement range / precision 30 7500mV ± (3% × reading 50mV)
The ground voltage limit setting range 30 ~ 7500mV 1mV/
Grounding voltage lower limit setting range 0 ~ 3000mV
Compensation voltage range 0 ~ 1000mV automatic measurement, can be opened, closed
Time setting range resolution of 1 ~ 999s / 1s/ step
Insulation resistance test output rated load / current 2VA(1000V/2mA) 2mA
The output voltage range of 500V/1000V <1% (DC /adjustment rate from no load to full load)
The output voltage ripple, the <1% (pure resistance1000V/1mA)
The output voltage precision / resolution ± (3% × set value 3V) 5V
Insulation resistance measuring range / accuracy ≤ 100MΩ: ± (3% × display value + 3 words);
>100 M Ω: ± (8% × display value 8 words)
Insulation resistance limit range of 2000 M
Insulation resistance limit setting range 0.3 ~ 2000M Ω 0.1M Ω / step (≤ 100M Ω M Ω / step), 1 (>100M
Test time range / resolution 1~999s 1s/ step
AC withstand voltage test output rated load 100VA(AC:5000V/20mA)
Frequency adjust the output voltage range of 500 ~ 5000V 50Hz/60Hz <3% rate (from no load to full load)
The output voltage setting range precision static: AC, 500 ~ 5000V; (3% ± x the set value 10V)
The breakdown current measurement accuracy of ± (3% × reading 0.03mA)
The breakdown current preset alarm range: 0.10 ~ 20.00mA; limit: 0.03 ~ 10.00mA; 0.01mA/
The compensation current range 0 ~ 10.00mA, automatic measurement, can be opened, closed
Test time range 1 ~ 999s 1s/
The slow rise time in the range of 0 ~ 100s 1s/
Leak testing output voltage range of external power supply or isolation device input
Leakage type static leakage, dynamic leakage
The output voltage range of measurement accuracy of AC 60 ~ 280V/45~65Hz: ± (0.5% × display value + 2 words)
Leakage current setting range: 0 ~ 9.999mA 0.001mA;limit: 0mA
The compensation current setting range 0 ~ 1000uA,automatic measurement, can be opened, closed
The leakage current measurement range precision of 0.050mA ~ 9.999mA/ DC ~ 10kHz: ± (3% × display value 10uA);
10K to 1MHz: ± (5% × display value 50uA)
Test time range 1 ~ 999s 1s/
Power test output voltage range of external power supplyor isolation device input
The power setting range resolution limit: 6 ~ 6000W limit:0 ~ 6000W 1W/
The output voltage range of measurement accuracy of AC 60 to 280V 45~65Hz: (0.5% ± * display value + 2words)
Current measuring range precision of AC 0.030 ~ 3.999A,4 ~ 25.00A;
45~65Hz: (0.5% ± * display value 0.020A)
Active power measurement range of 10 ~ 199.9W:accuracy of ± (0.5% × display value 5W);
200 to 6000W: ± (0.5% × display value 30W)
Power factor measurement precision of 0.100 ~ 1; ± (2% × display value + 2 words)
Test time range 1 ~ 999s 1s/
Instrument accessories:
Parts name type
Tester AN965-01
Auxiliary power line AN965-05
Junction box AN965-02