AN9633H交直流耐壓測試儀@AN9633H%
| 主要特點: |
| 技術參數: |
|
技術參數
|
AN9633H
交流耐壓、直流耐壓二合一
|
|
|
交
流
耐
壓
測
試
|
輸出電壓設定和測量范圍
|
100V~5000V AC 40mA 1V/步
|
|
輸出電壓調整率
|
±(2%×設定值+5V)
|
|
|
輸出電壓分辨率及精度
|
10V ±(2%×設定值+5V)
|
|
|
輸出頻率范圍及精度
|
50Hz/60Hz ±100ppM
|
|
|
輸出波形
|
正弦波 純阻負載下,200V以上失真度優于2%,100V~200V優5%
|
|
|
擊穿電流報警上下限設定
|
上限0.00~20.00mA 0.001mA/步;
下限0.000~9.999mA 0.001mA/步
|
|
|
擊穿電流測量范圍
|
0.000~3.500mA/3.50~40.00mA
|
|
|
擊穿電流測量分辨率
|
0.001mA/0.01mA
|
|
|
擊穿電流測量精度
|
0.2mA以上優于±(2%×顯示值+3個字);
0.2mA 以下優于±(2%×顯示值+10個字)
|
|
|
緩升/緩降/測試時間范圍
|
0.0~999.9s/0.0~999.9s/0.5~999.9s 0.1s/步
|
|
|
測線歸零
|
0~2.000mA,自動或手動消除空載時的偏差值
|
|
|
直流耐壓測試
|
輸出電壓設定和測量范圍
|
100V~6000V DC 10mA 1V/步
|
|
輸出電壓調整率
|
±(2%×設定值+5V)
|
|
|
輸出電壓分辨率及精度
|
10V ±(2%×設定值+5V)
|
|
|
直流電壓紋波系數
|
≤5%(在6kV,<1mA電流純阻性負載條件下測試)
|
|
|
擊穿電流報警上下限設定
|
上限0~9999uA 1uA/步;下限0.0~999.9uA 0.1uA/步
|
|
|
直流緩升電流上限設定范圍
|
12mA ON或OFF可設置
|
|
|
直流充電電流下限設定范圍
|
0.0~350.0uA
|
|
|
擊穿電流測量范圍
|
0.0~350.0uA/300~3500uA/3.00~9.99mA
|
|
|
擊穿電流測量分辨率
|
0.1uA/1uA/0.01mA
|
|
|
擊穿電流測量精度
|
0.0~350.0uA: ±(2%×設定值+5個字);
350.0~9999.0uA: ±(2%×設定值+2個字)
|
|
|
緩升時間設定/測試時間范圍
|
0.0~999.9s/0.5~999.9s 0.1s/步
|
|
|
測試歸零
|
0~200uA, 自動或手動消除空載時的偏差值
|
|
|
功能接口
|
開關量接口:啟動、停止信號輸入、調用1-8組,合格、報警、測試、故障信號輸出;掃描口、RS232(RS485)和打印口
|
|
|
外形尺寸W×H×D(mm)
|
400×156×475
|
|
AN9633H AC and DC withstand voltage tester@AN9633H%
Main features:
■ IEC60335, UL60335, GB4706.1-2005 content, GB4943 and other domestic and international safety standard test,with JJG795-2004, JJG690-2003 safety rules of metrological verification requirements;
A comprehensive solution ■ electrical strength safetydetection;
■ LCD screen display, in English bilingual interface;
■ slow rise and slow drop, scan test, line zero function;
■ alarm settings, open circuit, short circuit protection function;
■ intelligent identification, sound and light alarm, large character display;
■ 8 groups of *8 step condition setting memory and call out function;
■ advanced PWM control technology and DSPtechnology;
High speed detection ■ three project to test the fastest2.5S;
■ high precision, high efficiency, large capacity, smallvolume.
Technical parameters:
Technical parameters
AN9633H
AC voltage, DC voltage in
Hand in
Flow
Resistance to
Pressure
Test
Try to set the output voltage and measuring range of 100V~5000V AC 40mA 1V/
Output voltage regulation rate ± (2% × set value +5V)
The output voltage of the resolution and precision of 10V+ (2% x the set value +5V)
The output frequency range and precision of 50Hz/60Hz± 100ppM
Sine wave output waveform pure resistance load, 200Vdistortion is better than 2%, 100V~200V you 5%
The breakdown current alarm limits set upper limit0.00~20.00mA 0.001mA/ step;
Limit 0.000~9.999mA 0.001mA/ step
The breakdown current measuring range 0.000~3.500mA/3.50~40.00mA
The breakdown current measurement resolution of 0.001mA/0.01mA
The breakdown current measurement accuracy is better than ± (2% × 0.2mA above the display value of +3 words);
0.2mA is better than ± (2% × display value of +10 words)
The slow rise / fall / test time range from 0.0~999.9s/0.0~999.9s/0.5~999.9s 0.1s/
The line of zero 0~2.000mA, automatic or manual toeliminate the deviation of no-load value
DC withstand voltage test output voltage setting and measurement range of 100V~6000V DC 10mA 1V/
Output voltage regulation rate ± (2% × set value +5V)
The output voltage of the resolution and precision of 10V+ (2% x the set value +5V)
DC voltage ripple ≤ 5% (in 6kV, <1mA current pure resistive load conditions test)
The breakdown current alarm limits set upper limit0~9999uA 1uA/ step; limit 0.0~999.9uA 0.1uA/ step
DC slow rise and current limit set the range of 12mA ON or OFF can be set
DC charging current limit setting range 0.0~350.0uA
The breakdown current measuring range 0.0~350.0uA/300~3500uA/3.00~9.99mA
The breakdown current measurement resolution of 0.1uA/1uA/0.01mA
The breakdown current measurement accuracy of 0.0~350.0uA: + (2% x the set value +5 words);
350.0~9999.0uA: + (2% x the set value +2 words)
The slow rise time set / test time range from 0.0~999.9s/0.5~999.9s 0.1s/
The test of zero 0~200uA, automatic or manual toeliminate the deviation of no-load value
Interface switch interface: start, stop signal input, call 1-8group, qualified, alarm, test, fault signal output; scan port,RS232 (RS485) and print port
Dimensions of W × H × D (mm) 400 x 156 x 475