AN20015耐電壓測試儀校驗儀@AN20015%
| 主要特點: |
■ 完全符合《JJG795-2004耐電壓測試儀檢定規程》;
■ 交/直流電壓、電流±0.5%級測量精度,失真度、紋波系數±1.0%級精度
■ 特有定時時間測量,電流最大值保持、接地/浮地轉換等功能,可兼容數字、模擬式耐電壓測試儀;
■ 高安全性設計,高壓輸入后置,高絕緣防護;
■ 320×240蘭光液晶顯示,菜單式操作,數字鍵盤,使用簡單方便;
■ 選配計算機控制軟件――耐電壓測試儀校驗系統,方便數據存儲,證書打印。
| 適用對象: |
各級計量部門
|
技術參數: |
|
技術參數
|
AN20015
|
|
|
交、直流電壓
(直流正/負向)
|
測量范圍
|
0.500 kV ~ 15.00 kV
|
|
準確度
|
AC:0.500kV ~ 15.00kV, ±(0.5%×示值+2個字)
|
|
|
DC:0.500kV ~ 15.00 kV,±(0.5%×示值+2個字)
|
||
|
輸入阻抗
|
500MΩ
|
|
|
電壓分辨率
|
最小0.001kV
|
|
|
交、直流電流
(直流正/負向)
|
測量范圍
|
0.500mA ~ 200.0mA
|
|
準確度
|
AC:0.500mA ~ 200.0mA, ±(0.5%×示值+2個字)
|
|
|
DC:0.500mA ~ 200.0mA, ±(0.5%×示值+2個字)
|
||
|
交流電壓失真度
|
電壓輸入范圍
|
3kV ~ 15.00kV
|
|
基波輸入范圍
|
45 ~ 65Hz
|
|
|
量程范圍
|
1.00% ~ 10.0%
|
|
|
準確度
|
±(1%×量程+2個字)
|
|
|
直流電壓紋波系數
|
電壓輸入范圍
|
3.00kV ~ 15.00KV
|
|
測量范圍
|
1.00% ~ 10.0%
|
|
|
準確度
|
±(1%×示值+2個字)
|
|
|
電壓持續時間
|
測量范圍
|
0.10s ~ 999.99s
|
|
準確度
|
AC:±(1%×示值+1個信號周期)
|
|
|
DC:±(1%×示值+2個字)
|
||
|
分辨力
|
0.01s
|
|
|
通訊接口
|
RS-232(選配RS-485)
|
|
|
外觀顯示
|
320×240點陣液晶
|
|
|
外形尺寸W×H×D(mm)
|
400×156×310
|
|
|
選配附件
|
高壓交直流負載箱
耐電壓測試儀校驗裝置系統軟件(RS232接口) |
|
| 儀器配件: |
|
配件名
|
型號
|
|
|
必配
|
高壓測試線
|
AN200-01
|
|
接地線
|
AN000-03
|
|
|
選配
|
RS232通訊線
|
AN000-01
|
|
高壓交直流電流負載箱
|
FZX-1
|
|
AN20015 withstand voltage tester calibrator@AN20015%
Main features:
■ fully comply with the "JJG795-2004 verification regulation for withstanding voltage tester";
■ AC / DC voltage, current ± 0.5% level measurementaccuracy, distortion, ripple coefficient ± 1% level accuracy
■ specific timing measurement, the maximum current,grounding / floating conversion functions, can becompatible with digital, analog voltage resistance tester;
High safety design ■, high input, high insulation protection;
■ 320 × 240 blue light liquid crystal display, menu operation, digital keyboard, the use of simple and convenient;
■ matching computer control software -- resistance tocheck the system voltage tester, convenient data storage,certificate printing.
Applicable objects:
Metering departments at all levels
Technical parameters:
Technical parameters of AN20015
AC, DC voltage
(DC Positive / negative) measurement range of 0.500 kV~ 15 kV
The accuracy of AC:0.500kV ~ 15.00kV, ± (0.5% × showing the value of +2 words)
DC:0.500kV ~ 15 kV, ± (0.5% × showing the value of +2 words)
Input impedance 500M
Voltage minimum resolution of 0.001kV
AC, DC current
(DC Positive / negative) measurement range from 0.500mA to 200.0mA
The accuracy of AC:0.500mA ~ 200.0mA, ± (0.5% × showing the value of +2 words)
DC:0.500mA ~ 200.0mA, ± (0.5% × showing the value of +2 words)
AC voltage distortion input voltage range of 3kV to15.00kV
The fundamental input range of 45 ~ 65Hz
The range of 1% ~ 10%
The accuracy of ± (1% × range +2 words)
DC voltage ripple factor input voltage range of 3.00kV to 15.00KV
The measurement range of 1% ~ 10%
The accuracy of ± (1% × showing the value of +2 words)
Voltage duration measurement range from 0.10s to999.99s
AC: accuracy of ± (1% × showing the value of +1 signal cycle)
DC: ± (1% × showing the value of +2 words)
Resolution 0.01s
The communication interface of RS-232 (optional RS-485)
The appearance of 320 x 240 dot matrix liquid crystaldisplay
Dimensions of W × H × D (mm) 400 x 156 x 310
Optional accessories
High voltage load box
Withstand voltage tester calibrator system software(RS232 interface)
Instrument accessories:
Parts name type
Must be equipped with high-pressure test line AN200-01
Ground AN000-03
With the RS232 communication line AN000-01