常州同惠TH2881A 型匝間絕緣測試儀@TH2881A%
|
性能特點 : |
|
0-5000 V 測試電壓,連續可調 |
簡要介紹:
TH2881A型匝間絕緣測試儀采用“沖擊波形比較法”,將具有規定峰值和波前時間的沖擊電壓同時施加于相同設計的被測件與標準件上。通過比較兩個振蕩波形的差異,從而判斷電機繞組匝間絕緣的好壞。對電暈放電、局部短路、接線錯誤、嵌線錯誤、線圈平衡、相間短路等各類故障均能直觀判別。
|
常見的幾種測試波形 |
|
|
B.匝間絕緣不良 |
|
|
C.斷線波形 |
|
|
D.短路波形 |
|
|
技術參數: |
|
|
脈沖峰值電壓 |
0 — 5000 V 連續可調 |
|
峰值電壓準確度 |
±5%讀數±2字 (1 kV — 5 kV) |
|
峰值電壓調整率 |
≤ 10%×空載電壓 |
|
脈沖重復頻率 |
50 Hz |
|
波前時間 |
0.5 μs |
|
脈沖電容量 |
0.01 μF |
|
波形顯示方式 |
7″CRT |
|
最小測試電感量 |
100 μH |
|
峰值電壓顯示方式 |
LED 顯示 |
|
測量方式 |
雙路比較法 |
|
觸發方式 |
手控, 腳控 |
|
測試端 |
雙通道 |
一般技術指標
|
工作溫度, 濕度 |
0℃ — 40℃, ≤90% RH |
|
電源要求 |
198 V — 242 V AC, 47.5 Hz — 52.5 Hz |
|
功耗 |
≤ 150 VA |
|
尺寸(W×H×D) |
440 mm×215 mm×470 mm |
|
重量 |
約23 kg |
Changzhou Tonghui TH2881A interturn insulation tester@TH2881A%
Performance characteristics:
0-5000 V test voltage, adjustable
Inductance test range
Two high voltage test
The test waveforms of CRT display
The peak voltage of LED display
Equipped with foot control test switch
Brief introduction:
TH2881A interturn insulation tester using the "shock waveform comparison method", impulse voltage will have the provisions of the peak value and front time of the same design and applied to the DUT and standard parts.By comparing the difference between the two oscillationwaveform, so as to determine the motor winding inter turninsulation quality. The corona discharge, partial short,wrong wiring, wire embedding error, coil to balance,phase to phase short circuit and other kinds of failure can be visually distinguish.
Several common test waveform
A. normal form
Standard parts and measured the attenuation oscillationwaveform basically coincide with no significant difference,then the measured winding inter turn insulation fault free
B. insulation between turns bad
The part to be measured with standard waveform is inconsistent, that measured fault winding insulation. Fault display waveform moment can be accompanied byacoustic, or see the spark discharge and smell of ozone,the waveform display showing discharge burr and waveform.
C. breaking wave
DUT is winding, i.e. open, display waveform is an arc,sometimes discharge phenomenon appears in the gap.
D. short-circuit waveform
If the measured winding full short, the displayedwaveform is a horizontal line
Technical parameters:
The peak pulse voltage
0 - 5000 V continuously adjustable
The peak voltage accuracy
± 5% ± 2 word reading (1 kV - 5 kV)
The peak voltage adjustment rate
≤ 10% × no-load voltage
The pulse repetition frequency
50 Hz
Front time
0.5 μ
Pulse capacitor
0.01 μ
Waveform display
7 "CRT
Minimum test inductance
100 μ
The peak voltage display mode
LED display
Measuring mode
Two way comparison method
Trigger mode
Hand, foot control
The test end
Dual channel
General technical specifications
Temperature, humidity
0 ℃ - 40 ℃, ≤ 90% RH
Power requirements
198 V - 242 V AC, 47.5 Hz - 52.5 Hz
Power waste
More than 150 VA
Size (W * H * D)
440 mm × 215 mm × 470 mm
Weight
About 23 kg