CA6423接地電阻測試儀@CA6423%
|
測量方法
|
2極法/3極法
|
|
測量范圍
|
0.01~ 2000Ω (三檔自動量程)
|
|
分辨率
|
10mΩ / 100mΩ / 1Ω (根據量程范圍)
|
|
精度
|
±( 2% +1計數)
|
|
空載電壓
|
≤ 48 V
|
|
頻率
|
128 Hz
|
|
告警
|
3個LED錯誤指示燈,保證測量結果正確
|
|
電源
|
8 x 1.5V 電池
|
|
顯示屏
|
2000計數LCD數字顯示屏
|
|
安規
|
IEC 61010 & IEC 61557
|
|
尺寸
|
238 x 136 x 150 mm
|
|
重量
|
1.3kg
|
CA6423 ground resistance tester @CA6423%
CA6423 grounding resistance measurement range is 10mΩ to 1999 Ω, with automatic range switching function, can automatically select the best range gear. The operation is simple, just connect the test line, press the test button. Large LCD display can also indicates low battery, exceeding the measurement range, and the test lines connect the wrong stat
CA6423 uses 3 color terminal, convenient user terminalidentification. Instrument panel above the three LED lights, if an error occurs in the process of measuringsustainable to indicate to the user, so as to ensure theaccuracy and reliability of measurement.
CA6423 can protect 250Vac fuse
Product features:
The use of potential drop measurement
Measurement of grounding resistance (2 P or 3 P)
The automatic range switching function: automatically choose the best range gear
Anti jamming, anti noise design
Simple operation, wiring - button - Reading
The LED lamp at any time to remind the operator: too much interference, high auxiliary pile resistance or wrong wiring etc.
Power supply using the dry batteries
Rugged housing design, dustproof and rainproof (IP50)
Three terminal design, convenient connectionidentification
Can be used for measuring earthing continuity circuit connecting point (conductivity)
Product application:
CA6423 ground resistance tester, solid shell and the operation is simple, very suitable for maintenance personnel to carry out various tests. The anti interferencedesign, even in harsh testing environment (such as underhigh bulk current interference), still can make accurate measurements. CA6423 can be used for the following tests:
The 3 electrode method, for the measurement ofgrounding or grid grounding resistance. This method is often used to facilitate disconnection grounding orgrounding grid conditions, or grounding fault is not easy to take place.
The 2 electrode method, is used to measure thegrounding conductor connection continuity, and by measuring the field already exists (establish) ground toground resistance measurement. The measuring method is generally used in the urban areas, the use of thebuildings and auxiliary electrode cannot be arrangedunder the condition of. When in measurement, need to use well grounded in existing site environment in the body(such as iron pipe etc.).
Technical parameters:
Measurement method of 2 electrodes method /3 method
The measurement range of 0.01~ 2000 (three automatic range)
The resolution of 10m / 100M / 1 (according to the range)
Accuracy of ± (2% +1)
The no-load voltage ≤ 48 V
The frequency of 128 Hz
Alarm 3 LED error indicating lamp, ensure the measuringresult is correct
8 x 1.5V battery power
The 2000 count of LCD digital display screen
Safety of IEC 61010 & IEC 61557
Size 238 x 136 x 150 mm
Weight 1.3KG