          當前位置: 首頁 » 供應產品 » 儀器儀表 » 電子測量儀器 »CA6472數字式多功能接地電阻測試儀@CA6472%

          CA6472數字式多功能接地電阻測試儀@CA6472%

          <%=cpname%>
          產品價格: 0/人民幣 
          最后更新: 2014-04-14 16:17:06
          產品產地: 本地
          發貨地: 全國 (發貨期:當天內發貨)
          供應數量: 不限
          有效期: 長期有效
          最少起訂: 1
          瀏覽次數: 130
          詢價  試用會員產品
        2. 公司基本資料信息
          • 廈門欣銳儀器儀表有限公司
          • 楊清小姐 銷售
          • 會員[試用會員產品]
          • 郵件05921718@163.com
          • 手機13696902486
          • 電話
          • 傳真
          • 地址福州市臺江區福光南路379號武夷綠洲16座24號店面
          • 進入商鋪
           
          產品詳細說明

          CA6472數字式多功能接地電阻測試儀@CA6472%

          數字式多功能接地電阻測試儀CA6472,可用于測量:接地回路連接點電阻,接地電阻(傳統地樁法或鉗形法),土壤電阻率,接地耦合,以及跨步電壓、接觸電位等。
          當配合CA6474使用時,可用于測量輸配電塔桿或無線通訊塔桿的整體性接地電阻。
           
          CA6472接地電阻的測量范圍,為0.01 到 99.99kΩ,自動量程功能,可自動切換至最佳測量量程、并選用最佳測量頻率及最佳測量電流。測量頻率可從40 到 5078Hz組態設置(手動或自動);由于采用高抗干擾設計,可用于各種復雜惡劣的環境(如存在影響測量精度的大的離散電流)。
           
          CA6472 可存儲512組測量結果數據,可直接在儀器上查看,或通過DataView® 軟件將數據導入PC,自動生成報告、電位分布圖,測試頻率/電阻圖等等。
           
          產品特點:
          • 可用4極(4點)電位降法測量極低接地電阻,并可手動或自動選擇測量頻率,及自動進行測試導線補償
          • 使用3極電位降法測量接地電阻
          • 使用3極法測量接地耦合
          • 高電氣噪聲環境中,可手動選擇或自動頻率掃描40Hz到513Hz的測試頻率,確保測量精度
          • 可選擇測試電壓16V或32V ,測量電流可達250mA
          • 可使用4極法測量土壤電阻率,并自動計算顯示Rho(ρ)值;用戶可選擇Wenner法或Schlumberger法
          • 可進行2線或4線法測量直流電阻 (接地回路連接點電阻),具自動電流反向功能
          • 可用雙鉗法測量接地電阻 (不需要打輔助地樁)
          • 配合CA 6474和塔桿接地測試專用的電流鉗(GroundFlex®),可測量高壓輸配電搭桿腳的漏電流和接地電阻,而不需要斷開架空地線
          • 標配DataView® 軟件,可用于測量數據導入PC存儲、實時顯示、分析、生成報告及進行儀器組態設置
          • 自動關機電源管理功能
          • 自動識別所有的輔助電極連接及電極電阻
          • 儀器內存可存儲512組完整的測試數據
          • 使用光口隔離USB 通訊接口
          • 使用可充電鎳氫(NiMH )電池作為電源,可選購車充配件
          • 強固型防塵防雨外殼設計
          產品應用:
          • 使用3極法測量接地極或接地網的接地電阻,通常用于容易斷開接地連接導線的場合
          • 使用4極法測量土壤電阻率,用于定位土壤電阻率最低的位置,使接地工程更為合理、經濟
          • 接觸或跨步電位測量。在無法斷開接地導線的狀況下,且接地故障極有可能發生時,或電氣裝置與地面接觸的面積,與被測接地的大小可比擬時,建議進行電位測量。
          • 使用2線或4線法測量接地回路聯結點的導通性(連續性),測試電流為DC 250mA或更高,可用于檢測接地系統的所有聯結點的電阻。

          進行接地耦合測量與顯示,用于評估互不相連(獨立)的兩個接地電阻系統之間的影響

          技術參數:

           
          3極法
          4極法/選擇性測量
          雙鉗法
          土壤電阻率
          接地電位測量
          直流電阻
          測量
          配合CA6474
          測量
           量程
          0.01Ω-
          99.9kΩ
          0.001Ω-
          99.9Ω
          0.01Ω-
          500Ω
          0.01kΩ-
          99.9kΩ
          0.01mV-
          65.00V
          0.001Ω-
          99.9kΩ
          0.001Ω-
          99.99kΩ
           分辨率
          0.01-
          100Ω
          0.001-
          10Ω
          0.01-
          0.01-
          100Ω
          0.01mV-
          10mV
          2線法:0.01Ω-100Ω
          4線法:
          0.001Ω-10Ω
          0.001-10Ω
           精度
          ±(2%+1
          計數)
          ±(2%+1
          計數)
          ±(10%+1計數)
          ±(2%+1
          計數)
          ±(5%+1   計數)
          ±(2%+2   計數)
          ±(5%+1
          計數)
           空載電壓
          16或32VRMS
          ±16VDC
          16或32VRMS
           測試頻率
          41-
          5078Hz
          41-
          5078Hz
          自動:1367Hz
          手動:1367Hz/ 1611Hz/ 1758Hz
          41-
          128Hz
          41-
          128Hz
          DC
          41-5078Hz
           耦合測量
          -
          -
          -
          -
          -
          -
           輔助地樁電阻測試
          0.1Ω-
          100kΩ
          0.01Ω-
          100kΩ
          -
          -
          -
          -
          0.01Ω-
          100kΩ
           干擾電壓
          最大60V峰值
           
          最大60V
          峰值
           測量方法
          -
          -
          -
          Wenner&
          Schlum
          berger法
          自動計算
          -
          -
          -
           測量類型
          3線
          4線
          -
          4線
          3線
          2線或4線
          -
           電流測量
          -
          -
          -
          -
          -
          >200mA DC
          -
           內存容量
          可存儲512組測量結果
           通訊接口
          光口通訊線/USB
           防護等級
          IP53
           電氣安規
          CAT IV 50V, 符合IEC 61326-1 / IEC 61010 / IEC61557-1-4-5
           尺寸
          260 x 240 x 120 mm
           重量
          3.2 kg

          CA6472 digital multifunctional ground resistance tester@CA6472%

          Digital multifunctional ground resistance tester CA6472,can be used to measure: ground loop connection pointresistance, grounding resistance (traditional pile methodor a clamp method), soil resistivity, ground coupling, andthe step voltage, contact potential etc..

          As with the use of CA6474, can be used for themeasurement of grounding resistance of transmissiontower or wireless communication tower bar.

          CA6472 grounding resistance measurement range, 0.01 to 99.99k Ω, automatic range function, can automatically switch to the best measurement range, and selects the best frequency measurement and current measurement. Measuring frequency can be set from 40 to 5078Hz configuration (manually or automatically); due to the adoption of high anti-interference design, can be used for a variety of complex and bad environment (such as the existence of discrete current measurement accuracy)

          CA6472 can store 512 sets of measured data, candirectly view on the instrument, or by the DataView ®software to import the data into PC, automatically generate reports, potential distribution map, the test frequency / resistance graph etc..

          Product features:

          Available 4 pole (4 points) fall of potential method of measuring very low grounding resistance, and can bemanual or automatic selection of measuring frequency,and automatic test lead compensation

          The use of 3 electrode potential drop method of grounding resistance measurement

          The use of 3 coupling measurement method

          High electrical noise environment, can test the frequencyselected manually or automatic frequency scanning 40Hzto 513Hz, ensuring measurement accuracy

          Can choose the test voltage of 16V or 32V, measuring the current up to 250mA

          Can use 4 electrode measurement of soil resistivity, and automatic calculation shows that Rho (P) one value; the user can choose Wenner method or Schlumberger method

          Can be carried out in 2 line or 4 line method of measuring DC resistance (ground loop connection point resistance),with automatic current reverse function

          Grounding resistance measurement by double clamp method (no need to call the auxiliary pile)

          With CA 6474 and tower grounding test current clampspecial (GroundFlex ®), capable of measuring high voltage transmission and distribution on the rod foot of the leakage current and the grounding resistance, and does not need to disconnect the overhead ground wire

          The standard DataView ® software, can be used to measure the data into the PC memory, real-time display,analysis, report generation and instrument configurationsettings

          Automatic shutdown of power management features

          Automatic recognition of the auxiliary electrode and the electrode resistance all connections

          The instrument can test data memory stores a 512 set ofcomplete

          Use only isolated USB communication interface

          Use rechargeable nickel metal hydride (NiMH) battery as the power supply, purchase a car filled with optionalaccessories

          Rugged dustproof rainproof casing design

          Product application:

          Using the 3 electrode method measuring grounding andgrounding resistance, typically used to disconnect the ground connection conductor occasions

          Using the 4 electrode method for measurement of soil resistivity, soil resistivity minimum position, make thegrounding engineering is more reasonable, economy

          The contact and step potential measurement. Unable todisconnect the ground wire of the situation, and thegrounding fault is likely to occur, or electrical device ofthe contact area with the ground, and the measuredground size is comparable, suggest potential measurement.

          The use of 2 or 4 wire method to measure theconductivity of ground loop connection point (continuous),the test current is DC 250mA or higher, can be used for the detection of resistance grounding system allconnection points.

          Ground coupling measurement and display, for the assessment of each other (independent) effect between the two grounding resistance system

          Technical parameters:

          3 pole 4 pole / double clamp method selective measurement of soil resistivity grounding of DC resistance measurement

          Measurement with CA6474

          Measurement

          Range 0.01 Ω

          99.9k Ω to 0.001 Ω

          99.9 Omega 0.01 Omega

          500 Ω 0.01K Ω

          99.9k Ω 0.01mV

          0.001 - 65.00V

          99.9k Ω to 0.001 Ω

          99.99k

          Resolution 0.01-

          100 - 0.001-

          10 - 0.01-

          1 - 0.01-

          100 - 0.01mV-

          10mV 2 line method: 0.01 Ω -100

          4 line method:

          0.001 Ω -10 Ω 0.001-10

          Accuracy of ± (2%+1

          Count (2%+1)

          Count) ± (10%+1 count (2%+1)

          Count) ± (5%+1 counts) ± (2%+2 count (5%+1)

          Count)

          The no-load voltage of 16 or 32VRMS ± 16VDC 16 or32VRMS

          The frequency of test 41-

          5078Hz 41-

          5078Hz automatically: 1367Hz

          Manual: 1367Hz/ 1611Hz/ 1758Hz 41-

          128Hz 41-

          128Hz DC 41-5078Hz

          A - coupling measurement

          Auxiliary pile resistance test 0.1 Ω

          100k Ω to 0.01 Ω

          100k Ω - Omega - 0.0

          100K

          The maximum 60V peak value of 60V interference voltage

          Peak value

          Measuring methods -- Wenner&

          Schlum

          The Berger method

          Automatic calculation

          Measurement of type 3 line 4 line 4 line 3 line 2 line or 4line

          Current measurement, >200mA DC

          Memory can store 512 groups of measurement results

          Communication interface port communication line /USB

          Protection class IP53

          Electrical safety CAT IV 50V, with IEC 61326-1 / IEC 61010 / IEC61557-1-4-5

          Size 260 x 240 x 120 mm

          The weight of 3.2 kg

           


          在線詢盤/留言 請仔細填寫準確及時的聯系到你!
          您的姓名: * 預計需求數量: *    
          聯系手機: * 移動電話或傳真:
          電子郵件: * 所在單位:
          咨詢內容:
          *
           
          更多..本企業其它產品

          機電之家網 - 機電行業權威網絡宣傳媒體

          Copyright 2025 jdzj.com All Rights Reserved??技術支持:機電之家 服務熱線:0571-87774297

          網站經營許可證:浙B2-20080178-4

          主站蜘蛛池模板: 国产精品一区二区小视频| 欧美日韩精品在线视频| 亚洲女初尝黑人巨| 开心色怡人综合网站| 琪琪电影在线观看| 国产av无码专区亚洲av琪琪| 和艳妇在厨房好爽在线观看| 最近2018中文字幕2019高清| 成在线人免费视频| 免费看片高清不卡无码| 内射中出日韩无国产剧情| 息与子猛烈交尾在线播放| 99久久国产综合精品成人影院| 亚洲大尺度无码专区尤物| 国内揄拍国内精品人妻久久| 久久亚洲精品中文字幕无码| 人妻少妇精品无码专区| 日韩无码无卡码久久香蕉国产 | 亚洲中文中幕无码专区| 久久精品视频国产剧情| 美女极度色诱视频国产| 在线观看国产精美视频| 殴美一级无码免费| 成全动漫视频观看免费动漫| 久久精品久| 国产在线精品福利91香蕉| 在线看国产精品自拍内射| 无码福利青青久视频| 永久黄网站色视频免费直播| 最新精品国偷自产在线美女足| 精品动漫在线观看一区二区三区 | 亚洲制服无码一区二区三区| 久久精品亚洲中文无东| 性欧美VIDEOFREE高清大喷水| 激情一区二区三区成人文| 宝贝∽好硬∽好爽一再来视频| 久久久久国产一区二区三区| 久久人妻精品资援站| AV片在线观看| 美女黄色在线观看| 日本护士XXXXHD少妇|